2206-0835-REN

Permit

Remodel / Repair

Type

1207 19 Ave N

Location

Overview

A listing of the key features of the permit. To print this information, use the button below.

Printer Friendly Version

Description

Construction of new Caribou coffee location. This permit is for only the insulated shell building and additional permits will be required for insulation and fit up.The existing footings and foundation will be used for the new building. Will have drive through lane. Will have walk in lobby/seating. Exterior will consist of LP siding with stonework. Will have vinyl windows and tempered glass doors.

Details
Name Value
Porch False
Solar Energy System False
Fireplace True
Garage False
Deck False
Work Performed By Contractor
Occupant Load 49
Below Grade Construction Slab on Grade
Foundation Type Poured Concrete
Number of Bathrooms 1.00
Number of Bedrooms 0
Total Land Disturbance Area (ft²) 2000
Dwelling Units (DU) Added 1
Number of Exits 3
Building Use Group (Primary) A-2 Assembly Restaurants, Bars, Banquet Halls
Detailed Use Other
Establishment Name Caribou Coffee
Sprinkler Required False
1st Floor Area (ft²) 2000.00
Number of Floors 1
2nd Floor Area (ft²) 0.00
3rd Floor and Above Area (ft²) 0.00
Basement Area Finished (ft²) 0.00
Total Basement Area (ft²) 0.00
Total Construction Area (ft²) 2000.00
Construction Height (ft) 22.00
Project Costs 650000.00
Floodproof False
Flood Protection Elevation (FPE)
Contact Name Ryan Endres
Contact Type GC
Business Associated With 210 Construction
Contact Phone Number 7013889013
Contact Email ryendres@gmail.com
Number of Small Plant Units 0
Number of Larg Plant Units 2
Electrical Work Yes - by Contractor
Plumbing Work Yes - by Contractor
Gas Piping Work Yes - by Contractor
Heating or Air Conditioning Work Yes - by Contractor
Crane Required False
Impervious Surface Area (ft²) 2000.00
Roof Material Metal
Fireplace Fuel Gas
Fireplace Location Indoor
Fireplace Type Masonry
Quantity 1
Status Information
Name Complete Date
Application Submittal Yes 8/9/2022 8:54:27 AM
Completeness Review Yes 8/9/2022 8:54:53 AM
Plan Review Fee Payment Yes 8/9/2022 8:54:59 AM
Staff Review Yes 8/9/2022 8:57:58 AM
Approval Yes 8/9/2022 8:59:01 AM
Issuance Yes 8/9/2022 8:59:10 AM
Finalize No
Fees
Type Amount Paid
Building $3,204.67 Yes
Plan Review $422.43 Yes
Reviews
Division Status Reviewer
Inspections Complete / Approved Christine Rose
Engineering Not Required Christine Goldader
Fire Complete / Approved Ryan Erickson
Review Comments
Division Status Comment
Health Resolved This is shell only at this time, no review from health needed until interior fit up
Inspections Resolved Will this permit be for only a shell building with no insulation?(7/25 Insulated shell)
Inspections Resolved Will you be using the existing foundation for this structure?(7/25 Yes)
Inspections Resolved Sheet A-300 detail#2 shows no continuous insulation? IECC 2018 Table C402.1.3.
Inspections Resolved Sheet A-300 detail#10, the foundation insulation does not go to the top of the floor slab. 2018 IECC section C402.2.4.
Inspections Resolved Sheet A-300 details 2 and 3, will the glazing comply with section 2406.4.2?
Inspections Resolved Will there be any outdoor seating provided for this building? (Fixture counts)
Inspections Resolved It is the responsibility of the permit holder to verify the existence of any covenants or easements existing on this property.
Inspections Resolved If changes occur to the plans or specifications as a result of this review or for any other reason, revisions shall be issued as required and forwarded to this office.
Inspections Resolved A copy of this review, all responses, plans or specifications changes, or any other subsequent information pertaining to this project shall be provided to the contractor for his information.
Inspections Resolved This building and its associated site shall be accessible per IBC Section 1009, Chapter 11 and ANSI.
Inspections Resolved Complete and return the following form: ADAAG Conformance Statement (return copy, send original to address shown on the form)
Inspections Resolved Sheet S002, Special inspections and reporting (if required) shall be provided on this project per IBC Sections 1704 and 1705. The permit applicant shall submit a statement of special inspections as required by IBC Sections 1704 and 1705. A copy of a summary is attached for your use. Please provide a list of special inspectors and their qualifications. Special inspector shall provide this office with a final report documenting required special inspections and correction of any discrepancies noted in the inspections as required by IBC Section 1704.2.4. A certificate of occupancy may not be issued for this project until the final report is received by this office.
Inspections Resolved Provide information on compliance with the International Energy Conservation Code 2018. Comply with IECC Sections 401-405 or 407 as required. Computer-generated documentation (e.g. ComCheck) will be allowed to indicate total building performance as per IECC Section 407.6. Your summary must include building envelope, mechanical systems, water heating, interior lighting and electrical power systems.
Inspections Open Commissioning of new Buildings. Per the requirements of the International Energy Conservation Code, section C408, new buildings with 480 kBtu/h Cooling and 600 kBtu Heating capacities are required to undergo commissioning. It is designer’s responsibility to plan and apply all required commissioning procedures and fulfill the required documentation as prescribed in section C408. The registered design professional is required to provide copy of Commissioning Report to the Building’s owner within 90 days from date of receipt of Certificate of Occupancy (IECC sections C408.2.5 and C408.3.2). Statement from the registered design professional stating that commissioning report is provided to owner shall be submitted to our office.
Inspections Resolved There have been no plans submitted for the systems for this project. These systems (Plumbing, Mechanical and Electrical) shall comply with all the requirements of the City of Fargo and its adopted codes. These plans will be allowed as deferred submittals per IBC Section 107.3.4.1. Please review and approve these plans for compliance and forward them to this office for our review. No work can start on these systems until approved.
Inspections Resolved There is not approval for the fixture count as per table 2902.1 since this building is a shell building only.
Inspections Resolved Sheet C1, Please provide me with separated values for the building and the parking lot. These pieces will be permitted individually. You can also apply for the parking lot permit on-line and adjust the value for the building permit as needed, then resubmit.
Inspections
Type Date Status Inspection Items
Investigation / Walk-Through 3/9/2023 10:25:56 AM Passed
Consultation 1/13/2023 11:29:27 AM Passed
Consultation 4/26/2023 10:32:16 AM Passed
Energy / Insulation 3/10/2023 2:45:00 PM Passed
Grounding Electrode 9/28/2022 3:27:49 PM Passed
Footing 1/9/2023 1:00:00 PM Passed
Footing 9/23/2022 2:30:00 PM Passed
Foundation 9/28/2022 2:30:00 PM Passed
Framing Unscheduled
Framing 1/12/2023 10:30:00 AM Failed
Framing 1/17/2023 9:30:00 AM Failed
Framing 1/27/2023 9:45:00 AM Passed
Flood-Proof Floor / Slab 2/21/2023 10:45:00 AM Passed
Gas Piping Test Unscheduled
Final Building 4/25/2023 3:45:00 PM Failed
Final Building 5/3/2023 12:21:05 PM Passed
Temporary Electrical Service 10/14/2022 2:35:00 PM Passed
Above Ceiling Electrical 1/13/2023 2:30:00 PM Passed
Rough Electrical 3/6/2023 3:00:00 PM Passed
Rough Electrical 3/7/2023 8:50:00 AM Passed
Rough Electrical 3/13/2023 3:05:00 PM Passed
Rough Electrical 3/15/2023 4:00:00 PM Passed
Electrical Service 1/9/2023 10:40:00 AM Failed
  • Need to provide dated fult current label. SCCR is 42Ka.
  • Equipment grounding conductors are terminated in the service disconnect under 1 lug that is not rated for more than 1 wire. Need to separate.
  • Grounding electrode conductors are terminated in the service disconnect under 1 lug that is not rated for more than 1 wire. Need to separate.
Electrical Service 1/10/2023 10:00:00 AM Passed
  • Need to provide dated fult current label. SCCR is 42Ka.
  • Equipment grounding conductors are terminated in the service disconnect under 1 lug that is not rated for more than 1 wire. Need to separate.
  • Grounding electrode conductors are terminated in the service disconnect under 1 lug that is not rated for more than 1 wire. Need to separate.
Final Electrical 4/20/2023 11:00:00 AM Failed
  • East RTU has a 5kA rating and an available fault current of 6340 A.
  • Fault current to high at panel B for breakers installed. Available fault current is 11336A and breakers rated 10kA.
  • Receptacle outside bathrooms needs to be GFCI'D as it is within 6' of bathroom sink.
Final Electrical 4/21/2023 9:15:00 AM Passed
Contractors
Name License
210 Construction 46431A

Documents

View, download, and upload documents here.

Existing Documents
  • Permit (1).pdf (8/9/2022)
  • Permit.docx (8/9/2022)
  • Permit.pdf (8/9/2022)
  • Planning Approval_1207 19 Ave N (Caribou Coffee).pdf (6/29/2022)
  • New Value1207 19th Ave N (1).msg (8/4/2022)
  • Achitect reponse 1 2206-0835-NEWC (NEWC-COMM) 1207 19th Ave Caribou Shell Plan Review Response.msg (7/25/2022)
  • New Value1207 19th Ave N.msg (8/4/2022)
  • Plan Review Comments 2022-07-07.doc (7/7/2022)
  • Special Inspections sheet Signed form.msg (8/9/2022)
  • Special inspections Signed Doc.msg (8/3/2022)