Description

Ffit up lease space 128 for use as an iced cream and candy shop.

Details
Name Value
Sprinkler Required True
Project Costs 201300.00
Electrical Work
Gas Piping Work
Heating or Air Conditioning Work
Plumbing Work
Detailed Use
Establishment Name Scoop N Dough
Work Performed By Contractor
Occupant Load 50
Contact Name Kimberly Matteson
Business Associated With Design Resources Group
Contact Phone Number 701-499-3940
Contact Email km@drgteam.com
Contact Name Mike Orth
Business Associated With Christianson Companies
Contact Phone Number 701-499-3918
Contact Email morth@christiansoncompanies.com
Status Information
Name Complete Date
Application Submittal Yes 8/14/2019 9:19:35 AM
Completeness Review Yes 8/14/2019 9:19:39 AM
Plan Review Fee Payment Yes 8/14/2019 9:21:24 AM
Staff Review Yes 10/4/2019 9:41:58 AM
Approval Yes 10/4/2019 9:42:08 AM
Resubmission Yes 3/22/2021 2:38:04 PM
Staff Review Yes 3/26/2021 12:55:06 PM
Issuance Yes 3/29/2021 9:33:23 AM
Inspections Complete Yes 7/9/2021 9:06:33 AM
Certificate of Occupancy Yes 7/9/2021 9:06:50 AM
Finalize Yes 7/20/2021 7:49:32 AM
Fees
Type Amount Paid
Building $1,195.10 Yes
Plan Review $301.80 Yes
Reviews
Division Status Reviewer
Inspections Complete / Approved Peter Valkov
Planning Complete / Approved Kylie Bagley
Health Complete / Approved Laura Khadang
Fire Not Required Ryan Erickson
Inspections Complete / Approved Peter Valkov
Health Complete / Approved Laura Khadang
Review Comments
Division Status Comment
Planning Resolved 1. Confirm if the gross floor area on the routing sheet of 4,613 SF is accurate. Our previously approved plans for this building shell show the gross floor area SF as 4,917 SF.
Planning Resolved 2. Section 20-0701.B requires the use of “restaurant, fast-food” to provide 1 parking space per 75 SF of “customer service and dining area” or 1 parking space per 150 SF of “gross floor area” – whichever is greater. Provide further information and calculations for the “customer service and dining area” to the gross floor area.
Planning Resolved 3. Confirm if there is still room for 10 stacking spaces from the pick-up window in the drive-through lane.
Health Resolved Drop in sink designated as #11 on serving line needs to be hand wash sink only. Is a dump sink or a dipper well needed for the ice cream station/swirl machine rinse/coffee rinse?
Health Resolved Spoke with owner and #11 is a hand sink and dipper wells are on the equipment.
Inspections Resolved Restaurant shall be accessible per IBC, chapter 11 and ICC A117.1-2009.
Inspections
Type Date Status Inspection Items
Slab 4/9/2021 2:45:00 PM Passed
Above Ceiling Building Unscheduled
Framing 5/3/2021 9:00:00 AM Passed
Final Building 7/8/2021 1:33:00 PM Failed
Final Building 7/9/2021 10:18:00 AM Passed
Plumbing Ground Work 4/8/2021 1:00:00 PM Passed
Waste and Vent 4/22/2021 10:00:00 AM Passed
Final Plumbing 7/7/2021 9:00:00 AM Passed
Rough Electrical 4/30/2021 10:15:00 AM Passed
Final Electrical 7/7/2021 10:00:00 AM Failed
  • Need dated fault current label for RTU
  • Need arc guards in bathrooms
  • Some GFCI'S will not be readily accessible once coolers are installed under counter and behind glass case coolers
  • Need to GFCI receptacle for menu boards as they are in a location that needs GFCI protection for all recepracles.
  • Printed panel schedule is incorrect on right side toward bottom of schedule
Final Electrical 7/8/2021 11:15:22 AM Passed
  • Need dated fault current label for RTU
  • Need arc guards in bathrooms
  • Some GFCI'S will not be readily accessible once coolers are installed under counter and behind glass case coolers
  • Need to GFCI receptacle for menu boards as they are in a location that needs GFCI protection for all recepracles.
  • Printed panel schedule is incorrect on right side toward bottom of schedule
Contractors
Name License
Christianson Companies 24692A

Documents

View, download, and upload documents here.

Existing Documents
  • Certificate of Occupancy.doc (7/9/2021)
  • Permit.docx (3/29/2021)
About This Site

This site allows you to search permit data on-line. You may also create an account to submit permit applications, track the progress, and make payments.

Need help?

We’ve created a webpage that explains each permit or registration step-by-step and gives you detailed information about fees, required forms and related items.

Online Help >
Report a Problem

Trouble with your application or inspection request? Give us a call! 701.241.1561