2012-0737-NEWC

Permit

New Building

Type

4207 13 Ave S

Location

Overview

A listing of the key features of the permit. To print this information, use the button below.

Printer Friendly Version

Description

Construction of a new Tidal Wave Auto Spa - Automated Carwash. Required to be Floodproofed by WSEIA to an elevation of 904.50 .

Details
Name Value
Porch False
Solar Energy System False
Fireplace False
Garage False
Deck False
Work Performed By Contractor
Occupant Load 13
Below Grade Construction Slab on Grade
Foundation Type Concrete Block
Number of Bathrooms 1.00
Number of Bedrooms 0
Total Land Disturbance Area (ft²)
Dwelling Units (DU) Added 0
Number of Exits 5
Building Use Group (Primary) B Business
Detailed Use Other
Establishment Name Tidal Wave Auto Spa
Sprinkler Required False
1st Floor Area (ft²) 3394.00
Number of Floors 1
2nd Floor Area (ft²)
3rd Floor and Above Area (ft²)
Basement Area Finished (ft²)
Total Basement Area (ft²)
Total Construction Area (ft²) 3394.00
Construction Height (ft) 24.00
Project Costs 750000.00
Floodproof False
Flood Protection Elevation (FPE) 904.50
Contact Name John Lapointe
Contact Type Development Manager
Business Associated With Brightwork Real Estate
Contact Phone Number 8136903759
Contact Email jlapointe@brightworkre.com
Number of Small Plant Units 0
Number of Larg Plant Units 0
Electrical Work Yes - by Contractor
Plumbing Work Yes - by Contractor
Gas Piping Work Yes - by Contractor
Heating or Air Conditioning Work Yes - by Contractor
Crane Required False
Impervious Surface Area (ft²) 44431.00
Roof Material Metal
Status Information
Name Complete Date
Application Submittal Yes 1/14/2021 8:12:36 AM
Address Verification No
Completeness Review Yes 1/21/2021 8:26:04 AM
Plan Review Fee Payment Yes 1/21/2021 12:42:36 PM
Staff Review Yes 2/2/2021 8:12:23 AM
Returned for Revisions Yes 2/17/2021 1:41:36 PM
Resubmission Yes 3/1/2021 8:47:15 AM
Staff Review Yes 3/9/2021 10:55:21 AM
Returned for Revisions Yes 3/9/2021 10:55:48 AM
Resubmission Yes 3/9/2021 10:56:03 AM
Staff Review Yes 3/10/2021 2:47:51 PM
Returned for Revisions Yes 5/20/2021 8:46:56 AM
Resubmission Yes 5/20/2021 8:47:07 AM
Staff Review Yes 7/29/2021 11:32:40 AM
Approval Yes 7/29/2021 11:32:54 AM
Issuance Yes 7/29/2021 11:32:59 AM
Certificate of Occupancy Yes 8/16/2022 9:41:08 AM
Finalize Yes 8/17/2022 12:05:37 AM
Post Shot Requested Yes 12/21/2022 7:38:08 AM
Fees
Type Amount Paid
Building $3,526.50 Yes
Plan Review $705.30 Yes
Reviews
Division Status Reviewer
Inspections Revisions Needed Doug Desotel
Engineering Revisions Needed Ron Solberg
Planning Complete / Approved Kylie Bagley
Fire Complete / Approved Ryan Erickson
Inspections Revisions Needed Doug Desotel
Engineering Revisions Needed Ron Solberg
Planning Complete / Approved Kylie Bagley
Fire Complete / Approved Ryan Erickson
Inspections Complete / Approved Doug Desotel
Inspections Complete / Approved Doug Desotel
Engineering Complete / Approved Ron Solberg
Addressing Pending Wayne Lorshbough
Review Comments
Division Status Comment
Engineering Resolved Engineering Department comments for this project can be found under the parking lot project for the same address.
Inspections Resolved If changes occur to the plans or specifications as a result of this review or for any other reason, revisions shall be issued as required and forwarded to this office.
Inspections Resolved A copy of this review, all responses, plans or specifications changes, or any other subsequent information pertaining to this project shall be provided to the contractor for his information.
Inspections Resolved This building and its associated site shall be accessible per IBC Section 1009, Chapter 11 and ANSI.
Inspections Resolved Complete and return the following form: ADAAG Conformance Statement (return copy, send original to address shown on the form)
Inspections Resolved Safety glazing shall be provided as required per IBC Chapter 24. (3-1 Sheet Note 1G1.2)
Inspections Resolved There is a maximum of ½” height for the thresholds into the building per IBC Section 1010.1.7. (3-1-detail 2/A3.1
Inspections Resolved Special inspections and reporting (if required) shall be provided on this project per IBC Sections 1704 and 1705. The permit applicant shall submit a statement of special inspections as required by IBC Sections 1704 and 1705. A copy of a summary is attached for your use. Please provide a list of special inspectors and their qualifications. Special inspector shall provide this office with a final report documenting required special inspections and correction of any discrepancies noted in the inspections as required by IBC Section 1704.2.4. A certificate of occupancy may not be issued for this project until the final report is received by this office.
Inspections Resolved Restrooms – Tile must be smooth and non-porous. Grout must be non-sanded and sealed. FRP must be sealed with quality sealant to be compliant.
Inspections Resolved Per IBC Chapter 29 you are required to provide a service sink. Please provide location on plans and the wall surfaces. (not required)
Inspections Open Provide a list of sub contractors that will be working on this project. (3-1 Deferred)
Inspections Resolved Please provide the Geotechnical report for the building site. Sheet S1.1
Inspections Resolved Sheets C4.0 and A2.1, Shows the west exterior wall 5' from the property line. Provide wall ratings and opening protection requirements as per tables 602 and 705.8 (3-1 section 705.8.1 exception 2)
Inspections Resolved Sheet C6.0 , Will there be any elevation changes that will require a ramp between the car wash area and the equipment room?
Inspections Resolved Sheet 1G1.2 special Inspections, We are currently under the 2018 IBC.
Inspections Resolved Provide the geotechnical report for the building site.
Inspections Resolved Provide information on compliance with the International Energy Conservation Code 2018. Comply with IECC Sections 401-405 or 407 as required. Computer-generated documentation (e.g. ComCheck) will be allowed to indicate total building performance as per IECC Section 407.6. Your summary must include building envelope, mechanical systems, water heating, interior lighting and electrical power systems.
Inspections Resolved Sheet 1G1.2 Deferred submittals, Provide the Engineered Shop drawings for the vacuum Canopy (3-1 Deferred sub)( Rec 3/10/21)
Inspections
Type Date Status Inspection Items
Investigation / Walk-Through 4/11/2022 1:00:00 PM Passed
Investigation / Walk-Through 12/20/2022 2:02:14 PM Passed
Zoning 8/15/2022 9:30:00 AM Passed
Grounding Electrode 7/29/2021 2:54:07 PM Passed
Footing 10/18/2021 8:30:00 AM Passed
Footing 10/20/2021 11:00:00 AM Passed
Footing 12/23/2021 12:00:00 PM Passed
Foundation Passed
Foundation 7/29/2021 11:45:00 AM Passed
Foundation 9/7/2021 2:30:00 PM Passed
Foundation 10/7/2021 3:00:00 PM Passed
Foundation 1/3/2022 2:00:00 PM Passed
Slab 10/15/2021 12:00:00 PM Passed
Above Ceiling Building Unscheduled
Framing 10/25/2021 3:00:00 PM Void
Framing 10/27/2021 10:00:00 AM Passed
Framing 4/11/2022 1:00:00 PM Passed
Framing 7/8/2022 1:00:00 PM Passed
Framing 7/13/2022 9:30:00 AM Passed
Energy / Insulation Unscheduled
Certificate of Occupancy 8/15/2022 11:03:00 AM Passed
Final Building 8/15/2022 10:15:00 AM Passed
Final Parking Lot 8/15/2022 10:00:00 AM Passed
Investigation / Walk-Through 4/28/2022 1:45:00 PM Passed
General Electrical 8/5/2022 9:30:00 AM Passed
Electrical Service 12/27/2021 1:00:00 PM Failed
  • Need dated fault current label
  • Need #4 Cu to rebat
  • Green wires in service conduits are paralleled to the grounded conductors in conduits. This cant be done. Don't need the green conductors in conduit.
Electrical Service 1/4/2022 9:30:00 AM Passed
  • Need dated fault current label
  • Need #4 Cu to rebar
  • Green wires in service conduits are paralleled to the grounded conductors in conduits. This cant be done. Don't need the green conductors in conduit.
Final Electrical 8/11/2022 8:35:00 AM Failed
  • Need grounding electrode system for separate structure between canopies.
  • Need wet location rated exit lights.
  • Label spare breakers spare.
  • Need grounding electrode conductor to to step down transformer in electrical room.
Final Electrical 8/15/2022 10:10:00 AM Passed
  • Need grounding electrode system for separate structure between canopies.
  • Need wet location rated exit lights.
  • Label spare breakers spare.
  • Need grounding electrode conductor to to step down transformer in electrical room.
Sewer Service 8/16/2021 11:15:00 AM Passed
Sewer Service 8/17/2021 9:30:00 AM Passed
Sewer Service 8/17/2021 3:30:00 PM Failed
Sewer Service 8/19/2021 9:30:00 AM Failed
Sewer Service 4/27/2022 11:00:00 AM Passed
Sewer Service 9/14/2021 10:45:00 AM Failed
Sewer Service 9/15/2021 11:45:00 AM Failed
Sewer Service 9/16/2021 1:30:00 PM Failed
Sewer Service 9/24/2021 9:45:00 AM Failed
Sewer Service 10/20/2021 2:45:00 PM Passed
Contractors
Name License
Project Builders, Inc 43987A

Documents

View, download, and upload documents here.

Existing Documents
  • Archtetural and Civil Support Documents.pdf (3/1/2021)
  • Revised Architecural and Civl Permit Plans Fargo Tidal Wave.pdf (3/1/2021)
  • Tidal Wave App.pdf (1/14/2021)
  • Vacume Canopy plans 4207 13 Ave S - Fargo Tidal Wave Building Permit Number 7LBND1.msg (3/2/2021)
  • Tidal Wave Plans.pdf (1/14/2021)
  • Certificate of Occupancy.doc (8/16/2022)
  • Permit.docx (7/29/2021)
  • Receipt.doc (1/21/2021)
  • Civile Comment Respone Letter and support documents.pdf (3/1/2021)
  • 3-1 remaining items 4207 13 Ave S - Fargo Tidal Wave Building Permit Number 7LBND1.msg (3/1/2021)
  • Plan Review.doc (2/1/2021)
  • west wall openings 4207 13 Ave S - Fargo Tidal Wave - Building Permit Number 7LBND1.msg (2/11/2021)